Question

Will the EZ Touch panels be able to communicate to my Servo Drive?

Answer

Depending on the protocol that the servo drive supports, it is possible. We don't have an ASCII driver so the drive must support a protocol such as MODBUS RTU that can be driven by the touch panel. Realize that the panel is non-intelligent and has no scripting or expression features, so it can only turn on/off bits, display bits, read registers and write to registers. It is recommended that you have a PLC in between that supports the MODBUS RTU protocol. This way, you have an intelligent device for safety shut downs, etc...


FAQ Subcategory: None

This item was last updated on 2001-11-13
Document ID: 481


The information provided in the AutomationDirect knowledge base is provided "as is" without warranty of any kind. AutomationDirect disclaims all warranties, either express or implied, including the warranties of merchantability and fitness for a particular purpose. In no event shall AutomationDirect or its suppliers be liable for any damages whatsoever including direct, indirect, incidental, consequential, loss of business profits or special damages, even if AutomationDirect or its suppliers have been advised of the possibility of such damages. Some states do not allow the exclusion of limitation of liability for consequential or incidental damages so the foregoing limitation may not apply.