Question

Why doesn't my ACN drive run the motor when I hit the 'RUN' key?

Answer

The drive's default settings is to obeying the digital inputs for run, not the keypad.

To change this:
  • Press the up arrow until you the letters "Drv"
  • Hit "Enter"
  • Change the default value of 1 to a 0
  • Hit "Enter" to accept
  • Hit "Enter" again to confirm.
Then the drive should run off of the keypad.


FAQ Subcategory: None

This item was last updated on 2022-10-21
Document ID: 1647


The information provided in the AutomationDirect knowledge base is provided "as is" without warranty of any kind. AutomationDirect disclaims all warranties, either express or implied, including the warranties of merchantability and fitness for a particular purpose. In no event shall AutomationDirect or its suppliers be liable for any damages whatsoever including direct, indirect, incidental, consequential, loss of business profits or special damages, even if AutomationDirect or its suppliers have been advised of the possibility of such damages. Some states do not allow the exclusion of limitation of liability for consequential or incidental damages so the foregoing limitation may not apply.