Can the SR44 be configured for 'Auto Start/Re-start'?

Answer

Yes. Soft-start must be set up for remote starting:

Basic --> Starting (select remote starting)
  • Activate i/p 1 (110Vac applied to "S1" and "S0" terminals)
  • If soft-start is running and main & control powers are lost, then upon re-application of power, with i/p 1 activated, the soft-start will operate the connected motor. Note i/p 1 will still serve as the start/stop control.

Note: The SR44 line has been discontinued
For currently available soft starters, please see Soft Starters on the web site.


FAQ Subcategory: None

This item was last updated on 2021-02-16
Document ID: 1375


The information provided in the AutomationDirect knowledge base is provided "as is" without warranty of any kind. AutomationDirect disclaims all warranties, either express or implied, including the warranties of merchantability and fitness for a particular purpose. In no event shall AutomationDirect or its suppliers be liable for any damages whatsoever including direct, indirect, incidental, consequential, loss of business profits or special damages, even if AutomationDirect or its suppliers have been advised of the possibility of such damages. Some states do not allow the exclusion of limitation of liability for consequential or incidental damages so the foregoing limitation may not apply.