Question

When connecting to a P3 system, what do I do?

Answer

First, you must assign the Modbus addresses in the P3 Tag Database. There are no pre-assigned addresses, but the Tag DB will Auto-Increment and assign addresses according to data type (2 sequential addresses for any 32-bit data type)

Next, create a Modbus driver in Lookout. All of your P3 tags will be created under this object (normally called "Modbus1") Then, go thru the usual "Insert Expression" procedure to create your tags and select the "Modbus1" object. This will populate the "Contents" field with the various Modbus addresses and the different datatypes (no modifiers required). There are different tags for different types, D for double word integer, F for Real (Floating Point), and so forth.
NOTE: If you use F type, you will need to modify the Modbus driver object (choose Advanced when modifying this object, and check the box for "Modicon 32-bit etc). This will correctly display the P3 Float values.



FAQ Subcategory: None

This item was last updated on 2011-03-29
Document ID: 1365


The information provided in the AutomationDirect knowledge base is provided "as is" without warranty of any kind. AutomationDirect disclaims all warranties, either express or implied, including the warranties of merchantability and fitness for a particular purpose. In no event shall AutomationDirect or its suppliers be liable for any damages whatsoever including direct, indirect, incidental, consequential, loss of business profits or special damages, even if AutomationDirect or its suppliers have been advised of the possibility of such damages. Some states do not allow the exclusion of limitation of liability for consequential or incidental damages so the foregoing limitation may not apply.


Copyright © 1999- AutomationDirect.com. ALL RIGHTS RESERVED