Question

I am trying to use V7633 bit 13 to force the DL05 to power up in run. It doesn't seem to work. What gives?

Answer

This feature is available in firmware version 2.90 and later for the DL05 family of PLCs. Bit 13 in V-memory word V7633 needs to be on and the mode switch needs to be in the TERM position.



FAQ Subcategory: CPU & Programming

This item was last updated on 2003-05-23
Document ID: 12


The information provided in the AutomationDirect knowledge base is provided "as is" without warranty of any kind. AutomationDirect disclaims all warranties, either express or implied, including the warranties of merchantability and fitness for a particular purpose. In no event shall AutomationDirect or its suppliers be liable for any damages whatsoever including direct, indirect, incidental, consequential, loss of business profits or special damages, even if AutomationDirect or its suppliers have been advised of the possibility of such damages. Some states do not allow the exclusion of limitation of liability for consequential or incidental damages so the foregoing limitation may not apply.