DirectLogic MIL Testing Specifications
Due to the fact that some of the testing equipment is not available in Japan, Koyo's products are tested to comply to the MIL standards with a few differences described below.
Koyo (comply to MIL STD) | MIL STD | |
---|---|---|
Vibration range: | 10 to 500Hz | 5 to 500Hz |
Acceleration: | 1.5G | 1.5G |
Test Method: | Apply vibration with 1.5G for 30 min. at resonance. | Apply vibration with 1.5G for 30 min. at resonance. |
Koyo (comply to MIL STD) | MIL STD | |
---|---|---|
Peak Acceleration: | 50G | 40G |
Duration: | 11ms | 11ms |
Test Method: | Apply shock twice for each direction, x, y, and z axis. | Apply shock twice for each direction, x, y, and z axis. |
Operating Power: | Not applied. | Applied. |
Koyo (comply to MIL STD) | MIL STD | |
---|---|---|
Vibration range: |
10 to 500Hz |
5 to 500Hz |
Acceleration: | 1.5G | 1.5G |
Test Method: | Apply vibration with 1.5G for 30 min. at resonance. | Apply vibration with 1.5G for 30 min. at resonance. |
Koyo (comply to MIL STD) | MIL STD | |
---|---|---|
Peak Acceleration: | 50G | 40G |
Duration: | 11ms | 6-9ms |
Test Method: | Apply shock twice for each direction, x, y, and z axis. | Apply shock twice for each direction, x, y, and z axis. |
Operating Power: | Not applied. | Applied. |