Question Can the DL205 expand beyond the local rack?
Answer The D2-250-1 and D2-260 CPUs can be expanded using the D2-EM and D2-CM modules. See the DL205 User's Manual, Local Expansion I/O in Chapter 4 for details. Another method the I/O can be expanded is by adding remote I/O with the D2-240, D2-250, D2-250-1 and D2-260. The D2-240 uses the D2-RMSM (Remote Master) module. A total of 896 I/O points are available by using 2 Remote Master modules with 7 slave per module. The D2-250 and higher uses either the D2-RMSM module or the bottom port of the CPU. A total of 2048 I/O points are available using up to 7 Remote Master modules and the CPU port with 7 slaves per module and the CPU. The D2-230 can not be expanded beyond the local rack.

FAQ Subcategory:

This item was last updated on 01-21-2004
Document ID: 54


The information provided in the AutomationDirect knowledge base is provided "as is" without warranty of any kind. AutomationDirect disclaims all warranties, either express or implied, including the warranties of merchantability and fitness for a particular purpose. In no event shall AutomationDirect or its suppliers be liable for any damages whatsoever including direct, indirect, incidental, consequential, loss of business profits or special damages, even if AutomationDirect or its suppliers have been advised of the possibility of such damages. Some states do not allow the exclusion of limitation of liability for consequential or incidental damages so the foregoing limitation may not apply.